“
“The measurement of
dielectric spectroscopy over a broad frequency range of 0.01-10(7) Hz has been conducted to examine the segmental motions in poly[3-hydroxybutyrate-co-3-hydroxyvalerate] (PHBV) biopolymers. The ac conductivity at either low temperatures or high frequencies is almost temperature independent, indicating clearly that the nearly constant loss (NCL) phenomenon also takes place in polymers. The respective data were analyzed by adding a NCL term to the Jonscher relation. NCL in PHBV is discussed to be originated from the vibrational motion model. PHBV may have potential application as a biodegradable dielectric material. (C) 2009 American Institute of Physics. [DOI: 10.1063/1.3125271]“
“Purpose: Fatty liver infiltrations and fatty sparing impair diagnostic performance of grey-scale ultrasonography in differentiating malignant and benign focal liver lesions.
In the study, we present SC79 supplier our experience in diagnosing focal fatty liver infiltrations and focal fatty sparing with contrast-enhanced ultrasonography (CEUS) in comparison to grey-scale ultrasonography and contrast-enhanced computed tomography (CECT).
Material and selleck compound Method: The retrospective study group (n=82 patients), included 44 (53.7%) men, 38 (46.3%) women (aged 29-81 years, mean 55.8 years) with 48 focal fatty liver infiltrations and 34 focal fatty sparing. All patients underwent grey-scale ultrasonography
(US), CEUS using SonoVue (R) and CECT executed within the ON-01910 inhibitor 7 days.
Results: With US, CEUS and CECT focal fatty liver infiltrations were diagnosed in 22, 46 and 44 cases, respectively. The following values were obtained: sensitivity – 45.8%, 95.8% and 91.7%, specificity – 100% for all, accuracy – 95.2%, 99.6% and 99.3%, respectively. Focal fatty sparing was diagnosed in 16, 31 and 30 cases, respectively. The following values were obtained: sensitivity – 47.1%, 91.2% and 88.2%, specificity
– 99.8%, 100% and 100%, accuracy – 95.6%, 99.4% and 99.3%, respectively. No statistically significant differences were found in sensitivity of diagnosing focal fatty liver infiltrations and focal fatty liver sparing between CEUS and CECT. Sensitivity of grey-scale ultrasonography was significantly lower when compared to those of CEUS and CECT (p<0.001).
Conclusion: CEUS is as sensitive as CECT in focal fatty infiltrations and focal fatty sparing diagnosing. However, CEUS provides more information than CECT about the vasculature and enhancement pattern of focal fatty liver infiltrations.”
“We have investigated the details of phase separation in the electron-doped manganites Sm1-xCaxMnO3 (0.8 <= x <= 0.92) by using temperature dependent x-ray diffraction. The lattice of the low-temperature orthorhombic phase is distorted to various extents according to the strength of the coexisting monoclinic phase. Meanwhile, the room-temperature lattice becomes more distorted due to the increasing Jahn-Teller active Mn3+ ions by Sm3+ doping.